I/O Terminal Block
The Intellinet Network Camera provides an external I/O terminal block
which is used to connect input / output devices such as alarms or sensors.
The pin definitions are described below
PIN Definition Description Max. V/A
1
Ground
-
2
+ 5V DC
5V DC
0.5W
3
AUDIO_In(+)
Unbalanced, 1.4Vp-p, 1Vrms, terminal block
-
4
AUDIO_In(+)
Unbalanced, 1.4Vp-p, 1Vrms, terminal block
-
5
Digital Output
1
Uses an NPN transistor with the emitter connected to
the GND pin. If used with an external relay, a diode
must be connected in parallel with the load for
protection against voltage transients.
100 mA
24V
7
Digital Input 1
Connected to GND to activate, or leave floating (or
unconnected) to deactivate.
30V DC